1000W Single Output DC-DC Converter DCS-1000W

Features:


  • * 1U low profile 29.3mm
  • * High power density 10.7w/inch3
  • * Protections:Short circuit/Overload/Over voltage/Over temperature/Input polarity
  • * 2000VAC I/O Isolation
  • * Forced air cooling by built-in DC fan with fan speed control
  • * Output OK Signal
  • * 12V,0.25A auxiliary output
  • * 2 years warranty
  • Product Detail

    Product Tags

    MODEL DCS-1000L-12 DCS-1000L-24 DCS-1000L-48 DCS-1000H-12 DCS-1000H-24 DCS-1000H-48
    OUTPUT DC VOLTAGE 12V 24V 48V 12V 24V 48V
    RATED CURRENT 60A 40A 21A 60A 40A 21A
    CURRENT RANGE 0 ~ 60A 0 ~ 40A 0 ~ 21A 0 ~ 60A 0 ~ 40A 0 ~ 21A
    RATED POWER 480W 504W 504W 480W 504W 504W
    RIPPLE&NOISE (max.)Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p
    VOLTAGE ADJ. RANGE   11 ~ 15V 23 ~ 30V 46 ~ 60V 11 ~ 15V 23 ~ 30V 46 ~ 60V
    VOLTAGE TOLERNCE Note.3 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
    LINE REGULATION  ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
    LOAD REGULATION  ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
    SETUP, RISE TIME 500ms, 50ms at full  load
    INPUT  VOLTAGE RANGE Note.5 19 ~ 72VDC 72 ~ 144VDC
    EFFICIENCY (Typ.) 84% 88% 90% 85% 89% 92%
    DC CURRENT (Typ.) 23.5A/48VDC 11.6A/96VDC
    INRUSH CURRENT (Typ.) ~~~~ 100A/96VDC
    PROTECTION  OVERLOAD 105 ~ 125% rated output  power
    Protection type : Constant current limiting, shut down o/p voltage after about 5 sec., re-power on to recover
    OVER VOLTAGE 16 ~ 19V 30.8 ~ 35.2V 62 ~ 68V 16 ~ 19V 30.8 ~ 35.2V 62 ~ 68V
    Protection type : Shut down o/p voltage, re-power on to recover
    OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
    ENVIRONMENT WORKING TEMP. -25 ~ +60
    WORKING HUMIDITY 20 ~ 90% RH  non-condensing
    STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing
    TEMP. COEFFICIENT ±0.02%/℃ (0 ~ 50℃)
    VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
    SAFETY &EMC (Note 4)   WITHSTAND VOLTAGE I/P-O/P:2KVAC      I/P-FG:2KVAC      O/P-FG:0.5KVAC
    ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
    EMC EMISSION Compliance to EN55032 (CISPR32),EAC TP TC 020
    EMC IMMUNITY Compliance to EN61000-4-2,3,4,6,8, light industry level, criteria A, EAC TP TC 020
    OTHERS MTBF 106.7K hrs min.      MIL-HDBK-217F (25)°C
    DIMENSION 215*115*29.3mm (L*W*H)
    PACKING 0.75Kg; 20pcs/15.5Kg/CTN
    NOTE 1. All parameter NOT specially mentioned are measured at 24,48,96VDC Input, rated load and 25°C of ambient temperature.
    2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
    3. Tolerance: includes set up tolerance, line regulation and load regulation. 
    4.The power supply is considered a component which will be installed into a final equipment. 
    All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness.
    The final equipment must be re confirmed that it still meed EMC directives.
    For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
    5.Derating may be needed under low input voltages.Please check the derating curve for more details. 
    6.The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with 
    fan models for operating altitude higher than 2000m.

    ico1000W  Single Output DC-DC Converter   DCS-1000 series

    Dimension

    1314234

    Terminal Pin No. Assignment  
    Pin No. Assigment
    1 DC INPUT V+
    2 DC INPUT V-
    3 FG
    4~6 DC OUTPUT V-
    7~9 DC OUTPUT V+

     


  • Previous:
  • Next:

  • Related Products

    WhatsApp Online Chat !