100W Dual Output Switching Power Supply IRD-100W

Features:


  • * AC input range selectable by switch
  • * Protections: Short circuit / Overload / Over voltage
  • * Cooling by free air convection
  • * LED indicator for power on
  • * 100% full load burn-in test
  • * 2 years warranty
  • Product Detail

    Product Tags

    MODEL IRD-100Ⅰ IRD-100Ⅱ IRD-100Ⅲ IRD-100Ⅳ
    OUTPUT OUTPUT NUMBER CH1 CH2 CH1 CH2 CH1 CH2 CH1 CH2
    DC VOLTAGE 5V 12V 5V 24V 12V 5V 24V 5V
    RATED CURRENT 10A 4.2A 8A 2.5A 7A 3A 3.5A 3A
    CURRENT RANGE 2~10A 0.7~7.0A 1~10A 0.3~3.5A 0~8A 0~3A 0~4A 0~3A
    RATED POWER 100.4W 100W 99W 99W
    RIPPLE&NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 200mVp-p 120mVp-p 80mVp-p 120mVp-p 800mVp-p
    VOLTAGE ADJ. RANGE   CH1:4.75 ~ 5.5V CH1:4.75 ~ 5.5V CH1:11.4 ~ 13.2V CH1:22.8 ~ 26.4V
    VOLTAGE TOLERNCE  Note.3 ±2.0% ±10% ±2.0% ±8.0% ±2.0% ±3.0% ±2.0% ±3.0%
    LINE REGULATION      Note.4 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
    LOAD REGULATION    Note.5 ±1.0% ±5.0% ±1.0% ±4.0% ±1.0% ±2.0% ±1.0% ±2.0%
    SETUP, RISE TIME 2000ms, 30ms/230VAC      1200ms,30ms/115VAC at full load
    HOLD UP TIME (Typ.) 25ms/230VAC           20ms/115VAC at full load
    INPUT  VOLTAGE RANGE 88 ~ 132VAC/176~264VAC selected by switch        248~373VDC 
    FREQUENCY RANGE 47 ~ 63HZ
     EFFICIENCY (Typ.) 80% 82% 80% 82%
    AC CURRENT (Typ.) 2A/115VAC        1.2A/230VAC
    INRUSH CURRENT (Typ.) COLD START 45A
    LEAKAGE CURRENT <2mA / 240VAC
    PROTECTION  OVERLOAD 110 ~ 150% rated output power
    Protection type: Hiccup mode, recovers automatically after fault condition is removed
    OVER VOLTAGE CH1:5.75~6.75V CH2:5.75~6.75V CHI: 13.8 ~ 15.8V CH2:27.6~32.4V
    Protection Type: Hiccup mode, recovers automatically after fault condition is removed
    ENVIRONMENT WORKING TEMP. -20 ~ +70 (Refer to ”Derating Curve”)
    WORKING HUMIDITY 20%~ 90%,RH non-condensing
    STORAGE TEMP., HUMIDITY -40 ~ +85°C,  10 ~ 95%RH
    TEMP. COEFFICIENT ±0.03%/°C (0 ~ 50°C) on CH1 output
    VIBRATION 10-500HZ, 5G 10min./1 cycle, period for 60min. each along X, Y, Z axes
    SAFETY &
    EMC                    (Note 6)
    SAFETY STANDARDS UL60950-1, TUV60950-1 EAC TP 004 aprroved
    WITHSTAND VOLTAGE I/P-O/P:3KVAC  I/P-FG:2KVAC   O/P-FG0.5KVAC
    ISOLATION RESISTANCE I/P-O/P,I/P-FG:100MOhms/ 500VDC / 25℃/ 70%RH
    EMC EMISSION Compliance to EN55032 (CISPR32) Class B, EN61000-3-2, EAC TP TC 020
    EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN5502, EN61000-6-2,
    heavy industry level, criteria A, EAC TP TC 020
    OTHERS MTBF 320.7Khrs min.        MIL-HDBK-217F (25°C)
    DIMENSION 159*98*42MM (L*H*W)
    PACKING 0.55Kg; 30pcs/17.5Kg/0.97CUFT
    NOTE 1. All parameter NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
    2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & parallel capacitor.
    3. Tolerance: includes set up tolerance, line regulation and load regulation.
    4. Line regulation is measured from low line to high line at rated load.
    5. Load regulation is measured from 0% t0 100% rated load.
    6. The power supply is considered a component which will be installed to a final equipment.
    All the EMC tests are been executed by mounting kthe unit on a 230mm*230mm metal plate with 1mm of thickness.
    The final equipment must be re-confirmed that it still meets EMC directives.
    For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
    7. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with
    fan models for operating altitude higher than 2000mm(6500ft)

    LOGO1 100W  Dual Output Switching Power Supply  IRD-100 series

    Dimension

    sfdsvvrdvsefsageaefsdv

     

    Terminal Pin No. Assignment    
    Pin No. Assigment
    1 AC/L
    2 AC/N
    3 FG
    4,6 DC OUTPUT -V
    5 DC OUTPUT +V2
    7 DC OUTPUT +V1