100W Single Output LED Power Supply

Features:


  • Universal AC input / Full range ( up to 295VAC)
  • Built-in active PFC function
  • High efficiency up to 88.5%
  • Protections: Short circuit/ Over Current/ Over voltage/ Over temperature
  • Cooling by free air convection
  • IP67 design for indoor or outdoor instalations
  • Class 2 power unit
  • 100% full load burn-in test
  • High reliability
  • Suitable for LED lighting and moving sign applications
  • Compliance to worldwide safety regulations for lighting
  • Suitable for dry/ damp/ wet locations
  • 2 years warranty Note.5
  • Product Detail

    Product Tags

    MODEL WMC-100-20 WMC-100-24 WMC-100-30 WMC-100-36 WMC-100-42 WMC-100-48 WMC-100-54
    OUTPUT DC VOLTAGE 20V 24V 30V 36V 42V 48V 54V
    CONSTANT CURRENT REGION Note.5 13-20V 15.6-24V 19.5-30V 23.4-36V 27.3-42V 31.2-48V 35.1-54V
    RATED CURRENT 4.8A 4A 3.2A 2.65A 2.28A 2A 1.77A
    CURRENT RANGE 0~4.8A 0~4A 0~3.2A 0~2.65A 0~2.28A 0~2A 0~1.77A
    RATED POWER 96W 96W 96W 95.4W 95.76W 96W 95.58W
    RIPPLE&NOISE (max.)  2Vp-p 2.7Vp-p 3Vp-p 3.6Vp-p 4Vp-p 4.6Vp-p 5Vp-p
    VOLTAGE ADJ. RANGE(SVR1) 17~ 22V 22~ 27V 27~ 33V 33 ~ 40V 37 ~ 46V 43~ 53V 49~58V
    CURRENT ADJ. RANGE(SVR2) 3.12-4.8A 2.6-4A 2.08-3.2A 1.72-2.65A 1.48-2.28A 1.3-2A 1.15-1.77A
    VOLTAGE TOLERNCE   Note.2 ±10%
    LINE REGULATION      ±3.0%
    LOAD REGULATION  ±5.0%
    SETUP, RISE TIME 500ms / 230VAC      1200ms / 115VAC at full load
    INPUT  VOLTAGE RANGE  Note.3 90-295VAC               127-417VDC
    FREQUENCY RANGE 47 ~ 63HZ
    POWER FACTOR(Typ.) PF>0.97/115VAC, PF>0.95/230VAC, PF>0.9/277VAC at full load
    TOTAL HARMONIC DISTORTION THD<20% when output loading ≧75% at 115vac/ 230vac 

    input and output 

    loading ≧80% at 

    277VAC input

               
     EFFICIENCY (Typ.) 88% 89% 90% 90% 90% 91% 91%
    AC CURRENT (Typ.) 1.4A/115VAC        0.7A/230VAC         0.5A/277VAC
    INRUSH CURRENT (Typ.) COLD START 45A( twidth=85us measured at 50% Ipeak) at 230VAC
    LEAKAGE CURRENT <0.75mA / 240VAC
    PROTECTION OVER CURRENT 95-110%
    Protection type: Hiccup mode, recovers automatically after fault condition is removed
    SHORT CIRCUIT Hiccup mode, reconvers automatically after fault condition is removed
    OVER VOLTAGE 22.8- 26V 28-32V 34-38V 41-46V 47-52V 54-60V 59-68V
    Protection Type: Shut off o/p voltage, re-power on to recover
    OVER TEMPERATURE Shut off o/p voltage, re-power on to recover
    ENVIRONMENT WORKING TEMP. -30 ~ +70 (Refer to ”Derating Curve”)
    WORKING HUMIDITY 20%~ 95%,RH non-condensing
    STORAGE TEMP., HUMIDITY -40 ~ +85°C,  10 ~ 95%RH
    TEMP. COEFFICIENT ±0.03%/°C (0 ~ 50°C)
    VIBRATION 10-500HZ, 5G 10min./1 cycle, period for 72min. each along X, Y, Z axes
    SAFETY & EMC WITHSTAND VOLTAGE I/P-O/P:3.75KVAC  I/P-FG:2KVAC   O/P-FG: 0.5KVAC
    ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:>100MOhms / 500VDC / 25℃/ 70%RH
    EMC EMISSION Compliance to EN55015, EN61000-3-2 Class C (≧65% load); EN61000-3-3, EAC TP TC020
    EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level(sURGE 4KV), criteria B, EAC TP TC020
    OTHER DIMENSION 230*78*42mm (L*W*H)
    PACKING 0.9Kg; 20pcs/15.1Kg/CTN
    NOTE 1. All parameter NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
    2. Tolerance: includes set up tolerance, line regulation and load regulation.
    3. Derating may be needed under low input voltages. Please check the static characteristics for more details.
    4. Direct connecting to LEDs is suggested, but is not suitable for using addional drives.
    5. To fulfill requirements of the latesst ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.

     

     Dimension

    ww (1) ww (2)


  • Previous:
  • Next:

  • Related Products

    WhatsApp Online Chat !