60W Single Output LED Power Supply

Features:


  • Universal AC input / Full range ( up to 295VAC)
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Output voltage and constant current level adjustable
  • Built-in active PFC function
  • IP66 design for indoor or outdoor instalations
  • Class 2 power unit
  • Cooling by free air convection
  • 100% full load burn-in test
  • High reliability
  • Suitable for LED lighting and moving sign applications
  • Compliance to worldwide safety regulations for lighting
  • Suitable for dry/ damp/ wet locations
  • 2 years warranty
  • Product Detail

    Product Tags

    MODEL

    WMC-60-12

    WMC-60-15

    WMC-60-20

    WMC-60-24

    WMC-60-30

    WMC-60-36

    WMC-60-42

    WMC-60-48

    WMC-60-54

    OUTPUT

    DC VOLTAGE

    12V

    15V

    20V

    24V

    30V

    36V

    42V

    48V

    54V

    CONSTANT CURRENT REGION Note.5

    9-12V

    11.25-15V

    15-20V

    18-24V

    22.5-30V

    27-36V

    31.5-42V

    36-48V

    40.5-54V

    RATED CURRENT

    5A

    4A

    3A

    2.5A

    2A

    1.7A

    1.45A

    1.3A

    1.15A

    CURRENT RANGE

    0~5A

    0~4A

    0~3A

    0~2.5A

    0~2A

    0~1.7A

    0~1.45A

    0~1.3A

    0~1.15A

    RATED POWER

    60W

    60W

    60W

    60W

    60W

    61.2W

    60.9W

    62.4W

    60.1W

    RIPPLE&NOISE (max.)

    2Vp-p

    2.4Vp-p

    1.8Vp-p

    2.4Vp-p

    3Vp-p

    3.6Vp-p

    4Vp-p

    4.6Vp-p

    5Vp-p

    VOLTAGE ADJ. RANGE(SVR1)

    10.8~13.5V

    13.5~ 17V

    17~ 22V

    22~ 27V

    27~ 33V

    33 ~ 40V

    37 ~ 46V

    43~ 53V

    49~58V

    CURRENT ADJ. RANGE(SVR2)

    3.75-5A

    3-4A

    2.3-3A

    1.9-2.5A

    1.5-2A

    1.3-1.7A

    1.1-1.45A

    1.1-1.3A

    0.9-1.15A

    VOLTAGE TOLERNCE  Note.2

    ±10

    LINE REGULATION     

    ±3.0

    LOAD REGULATION

    ±5.0

    SETUP, RISE TIME

    500ms / 230VAC      1200ms / 115VAC at full load

    INPUT

     VOLTAGE RANGE  Note.3

    90-295VAC               127-417VDC

    FREQUENCY RANGE

    47 ~ 63HZ

    POWER FACTOR (Typ.)

    PF>0.97/115VAC, PF>0.95/230VAC, PF>0.9/277VAC at full load

    TOTAL HARMONIC DISTORTION

    THD<20% when output loading ≥75% at 115VAC/230VAC input and output loading≥80% at 277VAC input

     EFFICIENCY (Typ.)

    86%

    87%

    88%

    89%

    90%

    90%

    90%

    91%

    91%

    AC CURRENT (Typ.)

    0.8A/115VAC        0.4A/230VAC         0.3A/277VAC

    INRUSH CURRENT (Typ.)

    COLD START 30A/230VAC( twidth=85us measured at 50% Ipeak) at 230VAC

    LEAKAGE CURRENT

    <0.75mA / 240VAC

    PROTECTION

    OVER CURRENT

    95-110%

    Protection type: Hiccup mode, recovers automatically after fault condition is removed

    SHORT CIRCUIT

    Hiccup mode, reconvers automatically after fault condition is removed

    OVER VOLTAGE

    14.5 – 17V

    17.5-21V

    22.8-26V

    28-34V

    34-38V

    41-46V

    47-52V

    54-60V

    59-65V

    Protection Type: Shut off o/p voltage, re-power on to recover

    OVER TEMPERATURE

    Shut off o/p voltage, re-power on to recover

    ENVIRONMENT

    WORKING TEMP.

    -30 ~ +70 (Refer to “Derating Curve”)

    WORKING HUMIDITY

    20~ 90,RH non-condensing

    STORAGE TEMP., HUMIDITY

    -40 ~ +85°C,  10 ~ 95RH

    TEMP. COEFFICIENT

    ±0.03/°C (0 ~ 50°C)

    VIBRATION

    10-500HZ, 5G 10min./1 cycle, period for 72min. each along X, Y, Z axes

    SAFETY & EMC

    WITHSTAND VOLTAGE

    I/P-O/P:3.75KVAC  I/P-FG:2KVAC   O/P-FG: 0.5KVAC

    ISOLATION RESISTANCE

    I/P-O/P, I/P-FG, O/P-FG:100MOhms/ 500VDC / 25/ 70%RH

    EMC EMISSION

    Compliance to EN55015, EN61000-3-2 Class C (75% load); EN61000-3-3, EAC TP TC020

    EMC IMMUNITY

    Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level(sURGE 4KV), criteria B, EAC TP TC020

    OTHER

    DIMENSION

    152*51.5*33mm (L*W*H)

    PACKING

    0.5Kg; 20pcs/11Kg/CTN

    NOTE

    1. All parameter NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
    2. Tolerance: includes set up tolerance, line regulation and load regulation.
    3. Derating may be needed under low input voltages. Please check the static characteristics for more details.
    4. Direct connecting to LEDs is suggested, but is not suitable for using addional drives.
    5. To fulfill requirements of the latesst ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.

     

     

     Dimensionww (1) ww (2)


  • Previous:
  • Next:

  • Related Products

    WhatsApp Online Chat !