"Sincerity, Innovation, Rigorousness, and Efficiency" is definitely the persistent conception of our corporation to the long-term to establish alongside one another with customers for mutual reciprocity and mutual profit for Small Power Supply , 48v Dc Power Supply , Power Supply Housing , We have professional products knowledge and rich experience on manufacturing. We always believe your success is our business!
Free sample for Saa Power Supply Cord - 300W Single Output Switching Power Supply DPU-300W – BST(HONGKONG) Detail:

MODEL DPU-300-4 DPU-300-4.5 DPU-300-5
OUTPUT DC VOLTAGE 4V 4.5V   5V  
RATED CURRENT 60A 60A 60A
CURRENT RANGE 0~ 60A 0 ~ 60A 0 ~ 60A
RATED POWER 240W 270W 300W
RIPPLE&NOISE (max.)  Note.2 150mVp-p 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE   3.5~5V 4.0-5.5V 4V~5.5V
VOLTAGE TOLERNCE  Note.3 ±2.0% ±2.0% ±2.0%
LINE REGULATION      Note.4 ±0.5% ±0.5% ±0.5%
LOAD REGULATION    Note.5 ±1.5% ±1.5% ±1.0%
SETUP, RISE TIME 2500ms, 100ms/230VAC      2500ms, 100ms/115VAC
HOLD UP TIME (Typ.) 10ms/230VAC          8ms/115VAC at full load
INPUT  VOLTAGE RANGE 90~ 132VAC      180 ~ 264VAC      
FREQUENCY RANGE 47 ~ 63HZ
 EFFICIENCY (Typ.) 89.0% 89.0% 90.0%
AC CURRENT (Typ.) 3A/230VAC        5A/115VAC
INRUSH CURRENT (Typ.) Cold start 90A/ 230AVAC
LEAKAGE CURRENT <1mA 
PROTECTION  OVERLOAD A Type: 105 ~ 170% rated output power        B Type: 105 ~ 140% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE 4.6 ~ 5.4V 4.7 ~ 5.7V 5.7~ 7.0V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVER TEMPERATURE Protection type: Shut down O/P voltage, recovers automatically after temperature goes down
ENVIRONMENT WORKING TEMP. -35 ~ +70 (Refer to ”Derating Curve”)
WORKING HUMIDITY 20%~ 90%,RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85°C,  10 ~ 95%RH
TEMP. COEFFICIENT ±0.03%/°C (0 ~ 50°C)
VIBRATION 10-500HZ,5G 10min./1 cycle, period for 60min. each along X, Y, Z axes
SAFETY &
EMC (Note.5)
SAFETY STANDARDS UL60950-1, EAC TP 004 aprroved
WITHSTAND VOLTAGE I/P-O/P:3KVAC    I/P-FG:2KVAC     O/P-FG0.5KVAC
ISOLATION RESISTANCE I/P-O/P,I/P-FG:100MOhms/ 500VDC / 25℃/ 70%RH
EMC EMISSION Refer to EN55032 (CISPR32) Class A, EAC TP TC020
EMC IMMUNITY Refer to  EN61000-4-5, light industry level, criteria A, EAC TP TC020
OTHERS MTBF 226.4Khrs min.        MIL-HDBK-217F (25°C)
DIMENSION 216*82*30(L*W*H)
PACKING 0.67Kg; 20pcs/14.4Kg/0.91CUFT
NOTE 1. All parameter NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Please refer to “static characteristics”.
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire
terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance: includes set up tolerance, line regulation and load regulation.
5. Deratubg may be needed under low inout voltage. Please check the static characteriestic for more details.
6. The power supply is considered a component which will be installed into a final equipement.
The final equipment must be re-confirmed that it still meetsEMC directives.

ico    300W  Single Output Switching Power Supply DPU-300 series

Dimension

 124 13213

AC Input Terminal pin NO. Assignment      
Pin NO. Assignment Terminal
1, 2 AC/L HB-9500-300V-25A
3, 4 AC/N
5 FG

 

DC Output Terminal pin NO. Assignment        
Pin NO. Assignment Terminal
6 ~ 8 +V HB-9500-300V-40A
9 ~11 -V

 


Product detail pictures:

Free sample for Saa Power Supply Cord -
 300W  Single Output Switching Power Supply DPU-300W – BST(HONGKONG) detail pictures

Free sample for Saa Power Supply Cord -
 300W  Single Output Switching Power Supply DPU-300W – BST(HONGKONG) detail pictures

Free sample for Saa Power Supply Cord -
 300W  Single Output Switching Power Supply DPU-300W – BST(HONGKONG) detail pictures

Free sample for Saa Power Supply Cord -
 300W  Single Output Switching Power Supply DPU-300W – BST(HONGKONG) detail pictures

Free sample for Saa Power Supply Cord -
 300W  Single Output Switching Power Supply DPU-300W – BST(HONGKONG) detail pictures


Related Product Guide:
The Healing Power of Adjustable Beds
Electrical Power Supply Cords

We emphasize enhancement and introduce new solutions into the market just about every year for Free sample for Saa Power Supply Cord - 300W Single Output Switching Power Supply DPU-300W – BST(HONGKONG), The product will supply to all over the world, such as: United Arab emirates , Grenada , Niger , Our company absorbs new ideas, strict quality control, a full range of service tracking, and adhere to make high-quality products. Our business aims to "honest and trustworthy, favorable price, customer first", so we won the trust of the majority of customers! If you are interested in our products and services, please do not hesitate to contact us!
  • We have been looking for a professional and responsible supplier, and now we find it.
    5 Stars By Adam from Irish - 2015.06.30 17:29
    This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Phoebe from Swiss - 2015.06.21 17:11

    Related Products

    WhatsApp Online Chat !